Description
-
CN-8033 EtherCAT Network Adapter
- The CN-8033 EtherCAT I/O module supports standard EtherCAT protocol access.
- The adapter supports a Max. input of 1024 bytes and a Max. output of 1024 bytes. It supports 32 pcs of extended IO modules.
ODOT CN-8034 EtherNET/IP Network Adapter
- The CN-8034 Ethernet/IP I/O module supports standard Ethernet/IP protocol access. The adapter supports a Max. input of 504 bytes and a Max. output of 504 bytes.
- It supports 32 pcs of extended IO modules.
ODOT CN-8032 Profinet Network Adapter
- The CN-8032 Profinet network adapter supports standard Profinet IO Device Communication.
- The adapter supports MRP media redundancy, and it could realize ring network redundancy.
- It supports RT/IRT real-time and synchronous communication mode, with its RT real-time communication minimum period of 1ms and IRT synchronous communication minimum period of 250us.
- The adapter supports a maximum input of 1440 bytes, a maximum output of 1440 bytes, and the number of the extended IO modules it supports is 32.
CT-2228: 8 channel digital output/24VDC/ Source type
- The module supports 8-channel digital output, output high level effective, and output voltage 24V.
- The module could drive field equipment (relay, solenoid valve, etc).
- The module internal bus and field output are isolated by optocoupler.
- The module carries with 8 digital output channel LED indicator.
- The module has the functions of thermal shutdown and overcurrent protection.
- The module supports short circuit protection and overload protection.
CT-3713: 3-channel RTD-PT100 temperature acquisition module
- The module supports 3-channel RTD thermal resistance (PT100) temperature acquisition.
- The module could be connected to a 2-wire or 3-wire PT100 temperature sensor.
- The internal bus of the module and field input adopts magnetic isolation.
- The module carries with 3 analog input channel LED indicator.
- 15-bit ADC resolution.
CT-4234: 4-channel analog output
- 2 output ranges can be set(0-20mA?4-20mA).
- The module internal bus and field output adopts magnetic insulation.
- Single-terminal grounded together output mode.
ODOT CN-8031 Modbus TCP Network Adapter
- The CN-8031 Modbus TCP Network Adapter supports the standard Modbus TCP Server Communication, and Ethernet supports the cascade function of dual-port switches.
- This adapter supports access to 5 Modbus TCP clients simultaneously, supports Modbus function code 01/02/03/04/05/06/15/16 /23, supports the Modbus application of watchdog, supports the process data maximum sum of input and output of 8192 bytes, and supports number of the extension IO module of 32.
- Module carries with the diagnostic function and it could monitor the communication status of IO module in real time.
ODOT CN-8011 Modbus-RTU Network Adapter
- The CN-8011 Modbus-RTU network adapter supports standard Modbus-RTU communication, it supports function code of 01/02/03/04/05/06/15/16/23, and this device could monitor the IO module communication state in real time.
CT-3804: 4 channels Analog Input
- CT-3804: 4 channels Analog Input,Thermocouple( J type? K type? E type? T type? Stype? R type? B type? N type? C type)
- The module supports 4-channel thermocouple signal acquisition.
- The module carries with 4 analog indicators.
- The module supports 9 kinds of conventional thermocouple temperature measurement type.
- The internal bus of the module and field input adopts magnetic isolation.
- The module input channel supports TVS overvoltage protection.
- 24-bit ADC resolution (Σ-δ type.
CT-2718: 8 channel relay output 2A/30VDC/60W
- 8-channel relay normally on output.
- 8 LED channel indicators.
- Low on resistance (≤100mΩ)
- 250VAC/220VDC the max. switch voltage is 250VAC/220VDC.
CT-4158:8 channels Voltage Output 0~5VDC/0~10VDC/±5VDC/±10VDC,16bits
- The module supports 8 channels voltage signal output.
- Output range:0~5VDC, 0~10VDC, ±5VDC, ±10VDC, 16 bits.
- The module carries with 8 analog output LED indicators.
- Module output signal is single – ended common – grounded output.
ODOT CN-8032 Profinet Network Adapter
- The CN-8032 Profinet network adapter supports standard Profinet IO Device Communication.
- The adapter supports MRP media redundancy, and it could realize ring network redundancy.
- And it supports RT/IRT real-time and synchronous communication mode, with its RT real-time communication minimum period of 1ms and IRT synchronous communication minimum period of 250us.
- The adapter supports a maximum input of 1440 bytes, a maximum output of 1440 bytes, and the number of the extended IO modules it supports is 32.
ODOT CN-8012 Profibus-DP Network Adapter
- The CN-8012 PROFIBUS-DP network adapter supports access of standard PROFIBUS-DP, and the protocol version it supports is DPV0.
CT-121F:16 channel digital input/24VDC/ Sink type
- The module supports 8 channels of voltage signal input
- The module could collect 0~5VDC, 0~10VDC, ±5VDC, ±10VDC, with a 12-bit resolution
- The module carries with 8 analog input channel LED indicator
- The module input signal is a single ended common grounding input
CT-3158: 8 Channel Voltage Input
- The module supports 8 channels of voltage signal input.
- The module could collect 0~5VDC, 0~10VDC, ±5VDC, ±10VDC, with a 12-bit resolution.
- The module carries with 8 analog input channel LED indicator.
- The module input signal is a single ended common grounding input.
CT-4154 4 channels Voltage Output 0~5VDC/0~10VDC/±5VDC/±10VDC,16 bits
- The module supports 4 channels voltage signal output.
- Output range: 0~5VDC, 0~10VDC, ±5VDC, ±10VDC, 16 bits.
- The module carries with 4 analog output LED indicators.
- Module output signal is single – ended common – grounded output.
CT-3238: 8-channel analog input
- The module supports 8-channel current signal acquisition.
- The module can be configured for 0-20mA or 4-20mA current signal acquisition.
- The module supports 2-wire (non-loop output, external power supply required) or 4-wire current sensor input.
- The internal bus of the module and field input adopts magnetic insulation.
- The module input channel is connected to the field active analog signal current output sensor.
- The module channel equips with TVS overvoltage protection.
Contact Ti2