Product catalogue
Technical data, datasheets and CAD for the automation components we supply. Pricing is by quote.
1–48 of 58 products in Helmholz TB20
- Control technology and remote I/O › Remote I/O and network interface components › Helmholz TB20 (remove filter)
- Clear all
TB20 Analog Input Module - ±10 V, 0-10 V, 12 Bit
600-252-4AB01
Analogue input module (TB20 remote I/O); AI 2x U, ±10 V, 0-10 V, 1-5 V, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Input Module - ±10 V, 0-10 V, 12 Bit
600-252-4AD01
Analogue input module (TB20 remote I/O); AI 4x U, ±10 V, 0-10 V, 1-5 V, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Input Module - ±10 V, 0-10 V, 16 Bit
600-252-7BB01
Analogue input module (TB20 remote I/O); AI 2x U, ±10 V, 0-10 V, 1-5 V, Iso., 16 Bit; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Analog Input Module - ±10 V, 0-10 V, 16 Bit
600-252-7BD01
Analogue input module (TB20 remote I/O); AI 4x U, ±10 V, 0-10 V, 1-5 V, Iso., 16 Bit; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Analog Input Module - ±10 V, 0-10 V, 16 Bit
600-252-7BH21
Analogue input module (TB20 remote I/O); AI 8x U, ±10 V, 0-10 V, 1-5 V, Iso., 16 Bit; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Analog Input Module - ±24 V, 0-24 V, 12 Bit
600-252-4CB01
Analogue input module (TB20 remote I/O); AI 2x U, ±24 V, 0-24 V, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Input Module - ±24 V, 0-24 V, 12 Bit
600-252-4CD01
Analogue input module (TB20 remote I/O); AI 4x U, ±24 V, 0-24 V, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Input Module - AI 1/2x R, 16 Bit
600-253-4AB01
Analogue input module (TB20 remote I/O); AI 1/2x R, RTD, 16 Bit, 2/3/4-wire; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Input Module - AI 2/4x R, 16 Bit
600-253-4AD01
Analogue input module (TB20 remote I/O); AI 2/4x R, RTD, 16 Bit, 2/3/4-wire; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Input Module - AI 2x I, 0/4...20 mA, 12 Bit
600-250-4AB01
Analogue input module (TB20 remote I/O); AI 2x I, 0/4...20 mA, ±20 mA, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Input Module - AI 2x I, 16 Bit
600-250-7BB01
Analogue input module (TB20 remote I/O); AI 2x I, 0/4-20 mA, ±20 mA, Iso., 16 Bit; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Analog Input Module - AI 4x I, 0/4...20 mA, 12 Bit
600-250-4AD01
Analogue input module (TB20 remote I/O); AI 4x I, 0/4...20 mA, ±20 mA, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Input Module - AI 4x I, 16 Bit
600-250-7BD01
Analogue input module (TB20 remote I/O); AI 4x I, 0/4-20 mA, ±20 mA, Iso., 16 Bit; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Analog Input Module - AI 4x TC, Iso., 16 Bit
600-254-4AD02
Analogue input module (TB20 remote I/O); AI 4x TC, Iso., 16 Bit; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Analog Input Module - AI 8x I, 16 Bit
600-250-7BH21
Analogue input module (TB20 remote I/O); AI 8x I, 0/4-20 mA, ±20 mA, Iso., 16 Bit; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Analog Input Module - AI 8x R, 16 Bit
600-253-4BH21
Analogue input module (TB20 remote I/O); AI 8x R, RTD, 16 Bit, 2-wire; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Input Module - AI 8x TC, 16 Bit
600-254-4AH22
Analogue input module (TB20 remote I/O); AI 8x TC, Iso., 16 Bit; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Analog Output Module - ±10 V, 0-10 V, 12 Bit
600-261-4AB01
Analogue output module (TB20 remote I/O); AO 2x U, ±10 V, 0-10 V, 1-5 V, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Output Module - ±10 V, 0-10 V, 12 Bit
600-261-4AD01
Analogue output module (TB20 remote I/O); AO 4x U, ±10 V, 0-10 V, 1-5 V, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Output Module - AO 2x I, 0/4...20 mA, 12 Bit
600-260-4AB01
Analogue output module (TB20 remote I/O); AO 2x I, 0/4...20 mA, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Analog Output Module - AO 4x I, 0/4...20 mA, 12 Bit
600-260-4AD01
Analogue output module (TB20 remote I/O); AO 4x I, 0/4...20 mA, 12 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Counter Module - 2x Economy 24 V, 1 kHz, 32 Bit
600-300-1AB01
Counter module (TB20 remote I/O); 2x Economy 24 V, 1 kHz, 32 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Counter Module - 4 MHz, 32 Bit
600-310-7AA01
Counter module (TB20 remote I/O); 1x 5 V (RS422), 4 MHz, 32 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Counter Module - 4x Economy 24 V, 1 kHz, 32 Bit
600-300-1AD01
Counter module (TB20 remote I/O); 4x Economy 24 V, 1 kHz, 32 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Counter Module - 500 kHz, 32 Bit
600-300-7AA01
Counter module (TB20 remote I/O); 1x 24 V, 500 kHz, 32 Bit; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Input Module - DI 16x DC 24 V
600-210-0AP21
Digital input module (TB20 remote I/O); DI 16x DC 24 V; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Input Module - DI 16x DC 24 V, GND reading
600-210-0DP21
Digital input module (TB20 remote I/O); DI 16x DC 24 V, GND reading; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Input Module - DI 3x DC 24 V, 3-wire
600-210-0CC01
Digital input module (TB20 remote I/O); DI 3x DC 24 V, 3-wire; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Input Module - DI 4x AC 230 V, per channel N
600-211-0BD01
Digital input module (TB20 remote I/O); DI 4x AC 230 V, per channel N, type 1; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Digital Input Module - DI 4x DC 24 V
600-210-0AD01
Digital input module (TB20 remote I/O); DI 4x DC 24 V; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Input Module - DI 6x DC 24 V, 3-wire
600-210-0CF21
Digital input module (TB20 remote I/O); DI 6x DC 24 V, 3-wire; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Input Module - DI 8x AC 230 V, per channel N
600-211-0BH21
Digital input module (TB20 remote I/O); DI 8x AC 230 V, per channel N, type 1; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Digital Input Module - DI 8x DC 24 V
600-210-0AH01
Digital input module (TB20 remote I/O); DI 8x DC 24 V; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Input Module - DI 8x DC 24 V, GND reading
600-210-0DH01
Digital input module (TB20 remote I/O); DI 8x DC 24 V, GND reading; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Mix Module - DIO 4x In / 4x Out DC 24 V, 500 mA
600-230-0AH01
Digital input/output module (TB20 remote I/O); DIO 4x In / 4x Out DC 24 V, 500 mA; isolated from backplane bus; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Mix Module - DIO 8x Out / 8x In DC 24 V, 500 mA
600-230-0AP21
Digital input/output module (TB20 remote I/O); DIO 8x Out / 8x In DC 24 V, 500 mA; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 16x DC 24 V, 300 mA
600-220-0DP21
Digital output module (TB20 remote I/O); DO 16x DC 24 V, 300 mA, sink; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 16x DC 24 V, 500 mA
600-220-0AP21
Digital output module (TB20 remote I/O); DO 16x DC 24 V, 500 mA; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 16x DC 24 V, 700 mA
600-220-7AP21
Digital output module (TB20 remote I/O); DO 16x DC 24 V, 700 mA, High Feature; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 2x DC 24 V, 2 A
600-220-0BB01
Digital output module (TB20 remote I/O); DO 2x DC 24 V, 2 A; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 4x DC 24 V, 2 A
600-220-0BD01
Digital output module (TB20 remote I/O); DO 4x DC 24 V, 2 A; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 4x DC 24 V, 500 mA
600-220-0AD01
Digital output module (TB20 remote I/O); DO 4x DC 24 V, 500 mA; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 4x DC 24 V, 700 mA
600-220-7AD01
Digital output module (TB20 remote I/O); DO 4x DC 24 V, 700 mA, High Feature; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 4x Relay, 5 A
600-222-0AD21
Digital output module (TB20 remote I/O); DO 4x Relay, 5 A, AC 230 V, changeover; isolated from backplane bus; channel-to-channel isolation; hot-swap; IP20; 0 °C to +60 °C
Not In Stock
TB20 Digital Output Module - DO 8x DC 24 V, 300 mA
600-220-0DH01
Digital output module (TB20 remote I/O); DO 8x DC 24 V, 300 mA, sink; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 8x DC 24 V, 500 mA
600-220-0AH01
Digital output module (TB20 remote I/O); DO 8x DC 24 V, 500 mA; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Digital Output Module - DO 8x DC 24 V, 700 mA
600-220-7AH01
Digital output module (TB20 remote I/O); DO 8x DC 24 V, 700 mA, High Feature; isolated from backplane bus; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock
TB20 Energy Meter Module - 1 A
600-255-7AA21
Energy meter module (TB20 remote I/O); 1 A; hot-swap; IP20; 0 °C to +60 °C; DIN rail
Not In Stock