Festo

CPX Input/output Module - 2 inputs, 2 outputs

Part number CPX-2ZE2DA

Overview

Input/output module CPX-2ZE2DA Input/output module CPX-2ZE2DA Series: Individual component for electrical terminal CPX; Output ducts: 2 output channels; Input channels: 2 input channels; Switching input/output: Counter module

Technical data

Dimensions (W x L x H) (incl. interlinking block and connection technology), 50 x 107 x 50 mm
Grid dimension 50 mm
Product weight 130 g
Ambient temperature -5 – 50°C
Storage temperature -20 – 70°C
Degree of protection IP65, IP67
Corrosion resistance class CRC 1 - Low corrosion stress, (when installed)
Max. cable length 30 m
LABS (PWIS) conformity VDMA24364-B2-L
Approval UL - Recognized (OL)
Note on materials RoHS-compliant
Material housing Polymer
LED display 1 Group diagnostics, 10 Channel status, 2 Module diagnostics, 2 channel diagnostics
Diagnosis Operating-mode-dependent diagnostics
Number of outputs 2
Parameterisation Switch-on/off delay, Frequency output, Speed measurement, Pulse output, Pulse train, Rotational speed measurement, Frequency measurement, Cycle duration measurement, Motor operating mode, Determination of position, Pulse-width modulation, One-off counting, Continuous counting, Periodic counting
Operational voltage range DC 18 – 30 V
Nominal operating voltage DC 24 V
Intern power consumption nominal operating voltage Typically 35 mA
Number of inputs 2
Characteristic for inputs To IEC 1131-2, type 02
Switching level Signal 0: <= 5 V, Signal 1: >= 11 V
Switching logic for inputs PNP (positive switching)
Input debounce time 0.1 µs (0.2 µs, 0.4 µs, 0.8 µs, 1 µs, 2 µs, 4 µs, 8 µs, 10 µs, 50 µs, 100 µs, 500 µs, 1 ms, 3 ms, 10 ms, 20 ms parameterisable)
Max. residual current of inputs per module 2 A
Characteristic for outputs IEC1131-T2
Switching logic for outputs NPN (negative switching), PNP (positive switching), Push-pull driver
Max. residual current outputs per module 10 A
Max. power supply per channel 5 A adjustable (20 W lamp load)
Isolation channel - channel no
Isolation channel - internal bus Outputs - yes, when using an intermediate air supply
Fuse protection (short circuit) Internal electronic fuse per channel