Festo

CPX-AP Bus Interface - EtherCAT

Part number CPX-AP-I-EC-M12

Overview

EtherCAT interface; Series: Individual devices for automation system CPX-AP-I; Input channels: None; Function module: Fieldbus connection

Technical data

Dimensions (W x L x H) 45 x 170 x 35 mm
Type of mounting On H-rail via accessories, With through-hole
Max. number of modules 80
Product weight 186 g
Ambient temperature -20 – 60°C
Storage temperature -40 – 70°C
Relative air humidity 5 - 95%, Non-condensing
Degree of protection IP65, IP67
Note on degree of protection Unused connections sealed
Corrosion resistance class CRC 1 - Low corrosion stress
Max. cable length 50 m system communication
Note on max. cable length Power supply according to nominal voltage
LABS (PWIS) conformity VDMA24364-B2-L
Cleanroom suitability, measured according to ISO 14644-14 Element installed statically, no meaningful evaluation possible according to ISO 14644-1
CE mark (see declaration of conformity) To EU EMC Directive
UKCA marking (see declaration of conformity) To UK instructions for EMC
KC mark KC-EMV
Approval RCM trademark, c UL us listed (OL)
Certificate issuing authority UL E239998
Note on materials RoHS-compliant
Material housing PA, PC, Die-cast zinc, nickel-plated
Material o-ring FPM
Diagnostics via LED Diagnostics per module, EtherCAT® RUN, Power supply, electronics/sensors, Load power supply, System diagnostics, Service required
Diagnostics via bus APDD invalid, Load switch-off, Communication with AP module interrupted, Electronics/sensors overvoltage, Load overvoltage, Electronics/sensors undervoltage, Load undervoltage
Diagnostics per internal communication Module error, Output short circuit/overload, Short circuit/overload in sensor supply, Undervoltage in load supply
Fieldbus interface Ethernet
Field bus, protocol EtherCAT®
Fieldbus interface, function Bus connection incoming/outgoing
Field bus, connection type 2x socket
Field bus, connection system M12x1, D-coded to EN 61076-2-101
Field bus, connection pattern 4
Field bus interface, electrical isolation yes
Field bus interface, transmission rate 100 Mbit/s
Max. address volume, inputs 2048
Max. address volume, outputs 2048
Configuration support ESI file
Communication interface, function System communication XF20 OUT / XF21 OUT
Communication interface, connection type 2x socket
Communication interface, connection technology M8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores 4
Communication interface, protocol AP
Communication interface, screened yes
Power supply, function Incoming electronics/sensors and load
Power supply, connection type Plugs
power supply, connection system M8x1, A-coded to EN 61076-2-104
Power supply, number of pins/wires 4
Power transmission, function Outgoing electronics/sensors and load
Power transmission, connection type Socket
Power transmission, connection technology M8x1, A-coded to EN 61076-2-104
Power transmission, number of pins/wires 4
Note regarding operating voltage SELV/PELV fixed power supplies required, Note voltage drop
Nominal operating voltage DC of load 24 V
Permissible voltage fluctuation of load ± 25 %
Nominal DC operating voltage, electronics/sensors 24 V
Permissible voltage fluctuations for electronics/sensors ± 25%
Max. power supply 2 x 4 A (external fuse required)
Intrinsic current consumption at nominal operating voltage for electronics/sensors Typically 90 mA
Intrinsic current consumption at nominal operating voltage load Typically 5 mA
Power failure bridging 10 ms
Reverse polarity protection yes

Often bought with