PLC (CODESYS V3, IEC 61131-3); 800 MHz ARM Cortex-A9; 256 MB RAM / 256 MB flash; EtherCAT master, CANopen master; 16 digital inputs / 16 digital outputs (0.5 A); 8 analogue inputs, 4 analogue outputs; 24 V DC; DIN rail. Included options: S002 USB Serial Interface; S003 USB Ethernet; S004 USB Keyboard; S103 CODESYS CANopen Master; S104 CODESYS EtherCAT Master; S111 FTP Server; S112 NTP Client; S501 Backup/Restore Function; S503 Onboard Config Protection.

Technical data

Series B-Fortis CC-Prime
Function PLC (CODESYS V3, IEC 61131-3)
Berghof order number S-01020103-0400
Development environment CODESYS V3 (IEC 61131-3)
CPU 800 MHz ARM Cortex-A9 (single core)
RAM 256 MB
Flash 256 MB
Retain memory 100 kB
Ethernet 1x 10/100 Base, 3x RJ45 (integrated switch)
EtherCAT 1x EtherCAT, RJ45
CAN 1x CAN bus, RJ45 (opto-isolated)
Serial 1x RS232/485 combo, RJ45
Protocols Standard: EtherCAT master, CANopen master, NTP, FTP. Optional: Modbus RTU/TCP, SNMP, OPC UA, J1939, EtherNet/IP, PROFINET, BACnet, KNX, IoT
Visualisation Target visu (VNC server); optional WebVisu (web server, HTML5)
USB 1x Host USB 2.0, type A
Memory card 1x microSD slot (SDHC, up to 32 GB)
Real-time clock 1x RTC, battery buffered
Digital inputs 16
Digital outputs 16 (0.5 A)
Analogue inputs 8 (-10 V to +10 V, -20 mA to +20 mA, 6x PT100/PT1000), resolution 24 bit
Analogue outputs 4 (0 to 10 V), resolution 12 bit
Supply voltage 24 V DC (-15% / +20%), SELV, max. 5% AC component, reverse polarity protected
Current consumption max. 1.0 A at 24 V DC
Current consumption, digital outputs depending on output load, continuous 4x max. 2.7 A
Dimensions (W x H x D) 212 x 105 x 46.5 mm
Weight approx. 750 g
Mounting DIN rail NS 35/7.5 (EN 50022)
Certification CE (EN 61131-2), cULus (UL 61010-2-201)
Operating temperature 0 to 55 °C
Transport / storage temperature -20 to +70 °C
Relative humidity max. 85%, non-condensing
Emitted interference EN 61131-2; EN 61000-6-3 (living area)
Immunity to interference EN 61131-2; EN 61000-6-2 (industrial area)
Protection class III
Insulation strength EN 61131-2
Protection type IP20
Vibration Sinusoidal, EN 60068-2-6 test Fc, 10 to 150 Hz, 1 g (operation)
Shock resistance 15 g (approx. 150 m/s²), 10 ms, half-sine, EN 60068-2-27 test Ea