Festo
CPX-E Bus Module - up to 10 modules, 18.9 mm, 95 %
Part number CPX-E-EC
Overview
Bus module CPX-E-EC Bus module CPX-E-EC Series: Individual component for automation system CPX-E; Bus protocol/activation: EtherCAT®
Technical data
| Dimensions (W x L x H) | 42.2 mm x 76.5 mm x 125.8 mm |
|---|---|
| Grid dimension | 18.9 mm |
| Type of mounting | With H-rail |
| Max. number of modules | 10 |
| Product weight | 145 g |
| Mounting position | Vertical, Horizontal |
| Ambient temperature | -5 – 50°C |
| Note on ambient temperature | -5 - 60°C for vertical installation |
| Storage temperature | -20 – 70°C |
| Relative air humidity | 95 %, Non-condensing |
| Degree of protection | IP20 |
| Corrosion resistance class CRC | 0 - No corrosion stress |
| Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
| Protection against direct and indirect contact | PELV |
| LABS (PWIS) conformity | VDMA24364 zone III |
| CE mark (see declaration of conformity) | To EU EMC Directive, In accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) | To UK instructions for EMC, To UK RoHS instructions |
| KC mark | KC-EMV |
| Approval | RCM trademark, c UL us listed (OL) |
| Certificate issuing authority | UL E239998 |
| Note on materials | RoHS-compliant |
| Material housing | PA |
| Diagnostics via LED | EtherCAT® error, EtherCAT® RUN, Force mode, Modify, Module status, Power supply, electronics/sensors, Load power supply, System fault, Connection status |
| Diagnostics via bus | Wire break, Short circuit, Parameterisation error, Upper limit value violated, Overtemperature, Lower limit value not observed, Undervoltage |
| Fieldbus interface | EtherCAT® |
| Field bus, protocol | EtherCAT® |
| Fieldbus interface, function | Bus connection incoming/outgoing |
| Field bus, connection type | 2x socket |
| Field bus, connection system | RJ45 |
| Fieldbus interface, connection pattern | 995789 |
| Field bus, connection pattern | 8 |
| Field bus interface, electrical isolation | yes |
| Field bus interface, transmission rate | 100 Mbit/s |
| Fieldbus interface, note on transmission rate | 100 Mbit, fast switching Ethernet |
| Max. address volume, inputs | 64 |
| Fieldbus interface, max. address volume for inputs | 64 |
| Note on inputs | 62 bytes with I/O diagnostic interface, 63 bytes with status bits, 64 bytes without diagnostics |
| Max. address volume, outputs | 64 |
| Fieldbus interface, max. address volume for outputs | 64 |
| Note on outputs | 62 bytes with I/O diagnostic interface, 64 bytes with status bits, 64 bytes without diagnostics |
| System parameters | Diagnostic memory, Fail-safe response, Force mode, System start |
| Module parameters | Channel alarms bundling, Undervoltage diagnostics, Channel alarms for undervoltage |
| Configuration support | ESI file |
| Power supply, function | Electronics and sensors |
| Power supply, connection type | Terminal strip |
| Power supply, note on connection type | > 4 A and UL 2x terminal strip for power supply |
| power supply, connection system | Spring-loaded terminal |
| Power supply, connection pattern | 995847 |
| Power supply, number of pins/wires | 4 |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ± 25% |
| Power supply, conductor diameter | 0.2 – 1.5 |
| Power supply, note on conductor diameter | 0.2 - 2.5 mm² for flexible conductors without wire ferrule |
| Max. power supply | 8 A |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 64 mA |
| Power failure bridging | 20 ms |
| Reverse polarity protection | 24 V sensor supply against 0 V sensor supply |