Technical data
| Dimensions (W x L x H) | 42.2 mm x 76.5 mm x 125.8 mm |
|---|---|
| Grid dimension | 18.9 mm |
| Type of mounting | With H-rail |
| Max. number of modules | 10 |
| Product weight | 145 g |
| Mounting position | Vertical, Horizontal |
| Ambient temperature | -5 – 50°C |
| Note on ambient temperature | -5 - 60°C for vertical installation |
| Storage temperature | -20 – 70°C |
| Relative air humidity | 95 %, Non-condensing |
| Degree of protection | IP20 |
| Corrosion resistance class CRC | 0 - No corrosion stress |
| Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
| Protection against direct and indirect contact | PELV |
| LABS (PWIS) conformity | VDMA24364 zone III |
| CE mark (see declaration of conformity) | To EU EMC Directive, In accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) | To UK instructions for EMC, To UK RoHS instructions |
| KC mark | KC-EMV |
| Approval | RCM trademark, c UL us listed (OL) |
| Certificate issuing authority | UL E239998 |
| Note on materials | RoHS-compliant |
| Material housing | PA |
| Diagnostics via LED | Force mode, Module status, Network status, engineering port 1, EtherCAT® network status, Run, Power supply, electronics/sensors, Load power supply, System fault |
| Operator controls | DIL switch for RUN/STOP |
| IP address setting | DHCP, Via CODESYS |
| Fieldbus interface | Ethernet |
| Field bus, protocol | EtherCAT®, EtherCAT CoE, EtherCAT EoE, EtherCAT FoE, EtherCAT Master |
| Fieldbus interface, function | Outgoing bus connection |
| Field bus, connection type | Socket |
| Field bus, connection system | RJ45 |
| Fieldbus interface, connection pattern | 995789 |
| Field bus, connection pattern | 8 |
| Field bus interface, electrical isolation | yes |
| Field bus interface, transmission rate | 100 Mbit/s |
| Ethernet interface, connection type | Socket |
| Ethernet interface, protocol | EasyIP, Modbus® TCP, OPC UA, TCP/IP |
| Ethernet interface, function | Diagnostics |
| Ethernet interface, connection system | RJ45 |
| Ethernet interface, connection pattern | 995789 |
| Ethernet interface, number of pins/wires | 8 |
| Ethernet interface, transmission rate | 10 Mbit/s, 100 Mbit/s |
| Max. address volume, inputs | 64 |
| Max. address volume, outputs | 64 |
| System parameters | Diagnostic memory, Fail-safe response, System start |
| Module parameters | Channel alarms bundling, Undervoltage diagnostics, Channel alarms for undervoltage, Process value representation of analogue modules |
| Configuration support | CODESYS V3 |
| Additional functions | CoDeSys V3 with SoftMotion |
| CPU data | 128 MB RAM, Dual Core 650 MHz |
| Power supply, function | Electronics and sensors |
| Power supply, connection type | Terminal strip |
| Power supply, note on connection type | > 4 A and UL 2x terminal strip for power supply |
| power supply, connection system | Spring-loaded terminal |
| Power supply, connection pattern | 995847 |
| Power supply, number of pins/wires | 4 |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ± 25% |
| Power supply, conductor diameter | 0.2 – 1.5 |
| Power supply, note on conductor diameter | 0.2 - 2.5 mm² for flexible conductors without wire ferrule |
| Max. power supply | 8 A |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 65 mA |
| Power failure bridging | 20 ms |
| Reverse polarity protection | 24 V sensor supply against 0 V sensor supply |
| Programming software | CODESYS provided by Festo |
| Program memory | 12 MB user program |
| Processing time | Approx. 200 µs/1 k instruction |
| Function modules | And others, Read CPX-E module diagnostics, CPX-E diagnostic status, Copy CPX-E diagnostic trace |
| Buffering time real-time clock | 3 |
| Flag | 120 kB retentive data, CODESYS variable concept |
Similar products
Modbus TCP / Modbus RTU PLC Controller C3351-B01
Compact PLC for the CPX-E system, programmed with CODESYS V3 and communicating over EtherCAT. CPX-E-CEC-C1
B-Fortis CC-Prime 7 models
B-Fortis CC-Slim 6 models
B-FORTIS-CC-DIO Remote EtherCAT I/O Module B-Fortis CC-DIO - 16 Inputs B-FORTIS-CC-DIO 16/16 P
B-NIMIS MC-I/O Buskoppler EtherCAT Bus Coupler - 3 A B-NIMIS MC-I/O Buskoppler 3A